Abstract : The deconvolution technique is widely used for probe correction in the near field technique measurement. However, the measurement noise makes the result obtained by this method inefficient and requires the use of a very low noise measurement facility. In this paper, we present a method to improve the probe correction accuracy by an inverse filtering approach that takes into account the statistical characteristics of the measurement noise using the constrained least squares filtering algorithm (CLSF). Computations with EM software data of two different structures illustrate the reliability of the method.
https://hal-supelec.archives-ouvertes.fr/hal-00658604
Contributor : Mohammed Serhir <>
Submitted on : Tuesday, January 10, 2012 - 4:52:55 PM Last modification on : Monday, December 14, 2020 - 12:29:05 PM Long-term archiving on: : Wednesday, April 11, 2012 - 2:32:19 AM
Mohammed Anisse Moutaouekkil, Mohammed Serhir, Dominique Picard, Abdelhak Ziyyat. Near Field Probe Correction using Least Squares Filtering Algorithm. ICONIC 2011, Nov 2011, Rouen, France. pp.1-6. ⟨hal-00658604⟩