Enhanced direct instantaneous torque control of switched reluctance machine with phase current limitation

Abstract : In this work, an Enhanced Direct Instantaneous Torque Control (EDITC)of a Switched Reluctance Machine is explored. The main issue of regular direct instantaneous torque control (DITC) is that the current is measured but not controlled. Therefore, a new algorithm for hysteresis-controller was provided which included additional feature such as current limiter. Several simulations are presented which validates our controller over wide range of speed and torque.