Locating Multiple Soft Faults in Wire Networks Using An Alternative DORT Implementation

Abstract : Decomposition of the time reversal operator (DORT) was recently applied to the problem of detection and location of soft faults in wire networks and proved effectual when dealing with a single fault, even in the case of complex network configurations. In this paper, the case of location of multiple faults is addressed, first proving that the standard DORT formulation does not allow to take a clear decision about the individual position of each fault. An alternative version of the DORT, based on an updating procedure, is presented and demonstrated to enable accurate and selective location of multiple soft faults. The proposed procedure is also shown to allow estimating the reflection coefficient of each fault, thus giving access to their severity.
Document type :
Journal articles
Complete list of metadatas

Cited literature [20 references]  Display  Hide  Download

https://hal-supelec.archives-ouvertes.fr/hal-01198796
Contributor : Andrea Cozza <>
Submitted on : Monday, September 14, 2015 - 2:02:19 PM
Last modification on : Wednesday, September 16, 2020 - 5:45:27 PM
Long-term archiving on: : Tuesday, December 29, 2015 - 1:39:20 AM

File

TIM2015-EDORT_reviewed.pdf
Files produced by the author(s)

Identifiers

Citation

Moussa Kafal, Andrea Cozza, Lionel Pichon. Locating Multiple Soft Faults in Wire Networks Using An Alternative DORT Implementation. IEEE Transactions on Instrumentation and Measurement, Institute of Electrical and Electronics Engineers, 2016, 65 (2), pp.399-406. ⟨10.1109/TIM.2015.2498559⟩. ⟨hal-01198796⟩